Banner
Navigation

Navigation

loco-info.com
The reference for locomotives and railcars

Emperor Ferdinand Northern Railway “Koloss” and “Elephant”

Emperor Ferdinand Northern Railway series I No. 308 and 309

Austria-Hungary 1844 2 produced
“Koloss” PD

After the KFNB had ordered the first five freight locomotives in the 0-4-2 wheel arrangement in England at the end of the 1830s, they began to manufacture their own freight locomotives at Wiener Neustadt in 1844. Based on the 4-2-0 type from Norris, the bogie was converted into a fixed frame part and the second leading axle was replaced with a coupled axle. The cylinders were still mounted in an inclined position next to the smokebox and still drove the rear axle. Because of the low-pitched boiler, the ashpan of the deep firebox reached just above the top of the rails.

The locomotives were given the names “Koloss” and “Elephant” and were delivered in 1844. In 1853 and 1865 they received new boilers with a larger heating surface. Although they were normally only known by their names, they were internally numbered 43 and 44. According to the new scheme from 1869, they were classified as series I and given the numbers 308 and 309. They were retired two years later.

Technical data

General

Property as built new boiler
Built 1844 1853
Manufacturers Wiener Neustadt
Wheel arrangement 2-4-0 (Porter)
Gauge 1,435 mm (Standard gauge)

Dimensions and weights

Property as built new boiler
Length 7.53 m
Wheelbase 3.53 m
Empty mass 22 t
Service mass 24.6 t 24.7 t
Adhesion mass 18.1 t
Rigid wheelbase 3.53 m

Boiler

Property as built new boiler
Grate area 0.92 m² 1.12 m²
Firebox surface 6.2 m² 7.5 m²
Tube heating surface 69.6 m² 74.6 m²
Evaporative heating surface 75.8 m² 82.1 m²
Total heating surface 75.8 m² 82.1 m²

Power plant

Property as built new boiler
Driver diameter 1,180 mm
Boiler pressure 6.8 bar 6.3 bar
Expansion type simple expansion
Cylinders two, 381 x 562 mm

Power

Property as built new boiler
Power source steam
Estimated power 100 kW (136 PS) 110 kW (150 PS)
Starting effort 40.0 kN 37.0 kN

Calculated values

Property as built new boiler
Factor of adhesion 1 : 4.44 1 : 4.80
Optimal speed 16 km/h 18 km/h
Power-to-weight ratio 4.1 kW/t 4.5 kW/t
Heating Surface Equivalent 106.8 m² 119.6 m²
Cylinder volume/HSE 1 : 1,199.87 1 : 1,071.46
Adhesive weight/Total 1 : 1.36
Tractive force/Heating surface 1 : 11.01 1 : 9.42
Grate area/Heating surface 1 : 82.39 1 : 73.30
Firebox/Tube surface 1 : 11.23 1 : 9.95
Auf Deutsch umschalten

Settings

Your settings are retained for this browser session only.

Consent to cookies

We use cookies to save your display settings. If you decline, the settings are retained only for the current browser session.