Pennsylvania classes M1 and M1a
United States 1923 301 produced
The PRR's first Mountain was created in 1923 by placing the boiler of the Class I1s Decapod on a new frame. After testing the prototype, 175 production locomotives were built by Baldwin and 25 by Lima. In 1930, 50, 25 and 25 locomotives from Baldwin, from Altoona and from Lima followed of the M1a, which had been improved in details. Not only could they pull heavy passenger trains at high speeds, they were also not overwhelmed by freight trains with more than 100 cars and 4,000 short tons in the mountains. 40 M1a were converted to the M1b in 1946 by increasing the boiler pressure by 20 psi and increasing the size of the firebox.
Technical data
General
| Property | M1 | M1a |
|---|---|---|
| Built | 1923, 1926 | 1930 |
| Manufacturers | Altoona, Baldwin, Lima | |
| Wheel arrangement | 4-8-2 (Mountain) | |
| Gauge | 1,435 mm (Standard gauge) | |
Dimensions and weights
| Property | M1 | M1a |
|---|---|---|
| Length | 26.71 m | |
| Wheelbase | 12.51 m | 12.75 m |
| Total wheelbase | 24.18 m | |
| Service mass | 175 t | 176.9 t |
| Adhesion mass | 121.1 t | 122.9 t |
| Total mass | 275.3 t | 348.5 t |
| Rigid wheelbase | 5.74 m | |
| Axle load | 32.9 t | 31.8 t |
| Water capacity | 45,349 l | 83,355 l |
| Fuel capacity | 16.8 t (coal) | 28.6 t (coal) |
Boiler
| Property | M1 | M1a |
|---|---|---|
| Grate area | 6.494 m² | |
| Firebox surface | 36.883 m² | |
| Tube heating surface | 399.762 m² | 399.948 m² |
| Evaporative heating surface | 436.645 m² | 436.831 m² |
| Superheater surface | 151.618 m² | 151.432 m² |
| Total heating surface | 588.3 m² | |
Power plant
| Property | M1 | M1a |
|---|---|---|
| Driver diameter | 1,829 mm | |
| Boiler pressure | 17.2 bar | |
| Expansion type | simple expansion | |
| Cylinders | two, 686 x 762 mm | two, 711 x 762 mm |
Power
| Property | M1 | M1a |
|---|---|---|
| Power source | steam | |
| Estimated power | 2,610 kW (3,549 PS) | |
| Starting effort | 287.1 kN | 308.8 kN |
Calculated values
| Property | M1 | M1a |
|---|---|---|
| Factor of adhesion | 1 : 4.14 | 1 : 3.91 |
| Optimal speed | 56 km/h | 51 km/h |
| Power-to-weight ratio | 14.9 kW/t | 14.8 kW/t |
| Heating Surface Equivalent | 924.3 m² | 924.1 m² |
| Cylinder volume/HSE | 1 : 609.06 | 1 : 655.14 |
| Adhesive weight/Total | 1 : 1.45 | 1 : 1.44 |
| Tractive force/Heating surface | 1 : 10.19 | 1 : 10.96 |
| Grate area/Heating surface | 1 : 90.59 | |
| Firebox/Tube surface | 1 : 10.84 | |
| Total/Superheater | 1 : 2.88 | |