Banner
Navigation
loco-info.com
The reference for locomotives and railcars

Santa Fe classes 3800 and 3876

United States 1919 140 produced
The brand-new No. 3911 at San Bernardino, California collection Taylor Rush

The class 3800 and its subclass 3876 were the last 2-10-2 locomotives of the Santa Fe. After their predecessors had been created by adding a trailing axle to a 2-10-0, the 3800 was created by lengthening a 2-8-2, what allowed for a much larger firebox. The 75 members of the class 3800 were built by Baldwin between 1919 and 1923 and were operated at a boiler pressure of 200 psi. They carried the numbers from 3800 to 3875, with the exception of the number 3829 that was given to a 2-10-4.

Between 1924 and 1927, 65 locomotives followed which got the numbers between 3876 and 3940. Due to some changes in the boiler, they are usually viewed as a subclass. They were operated at 220 psi, while the earlier ones were upgraded to 210 psi. While 36 of the main class had been built as coal burners and only the rest as oil burners, all of the subclass had originally been built as oil burners. 23 of these were built with a trailing truck booster, while 15 others got larger tenders which can be found in the specs for the 3876 given below. Some were later rebuilt with thermic syphons. While most of the class 3800 and its subclass were still running in 1950, they were gone by 1956.

Technical data

General

Property 3800 3876
Built 1919-1923 1924-1927
Manufacturers Baldwin
Wheel arrangement 2-10-2 (Santa Fé)
Gauge 1,435 mm (Standard gauge)

Dimensions and weights

Property 3800 3876
Wheelbase 12.53 m
Total wheelbase 26.06 m 28.28 m
Service mass 179.9 t 183.8 t
Adhesion mass 140.2 t 142.7 t
Total mass 315.3 t 354.3 t
Rigid wheelbase 6.71 m
Axle load 29.7 t
Water capacity 56,781 l 75,708 l
Fuel capacity 18,927 l (oil) 27,141 l (oil)

Boiler

Property 3800 3876
Grate area 8.203 m²
Firebox surface 38.741 m²
Tube heating surface 456.247 m² 433.858 m²
Evaporative heating surface 494.988 m² 472.598 m²
Superheater surface 120.588 m² 124.955 m²
Total heating surface 615.6 m² 597.6 m²

Power plant

Property 3800 3876
Driver diameter 1,600 mm
Boiler pressure 13.8 bar 15.2 bar
Expansion type simple expansion
Cylinders two, 762 x 813 mm

Power

Property 3800 3876
Power source steam
Estimated power 2,647 kW (3,599 PS) 2,740 kW (3,725 PS)
Starting effort 345.7 kN 380.3 kN

Calculated values

Property 3800 3876
Factor of adhesion 1 : 3.98 1 : 3.68
Optimal speed 47 km/h 43 km/h
Power-to-weight ratio 14.7 kW/t 14.9 kW/t
Heating Surface Equivalent 929.9 m² 916.2 m²
Cylinder volume/HSE 1 : 797.24 1 : 809.13
Adhesive weight/Total 1 : 1.28 1 : 1.29
Tractive force/Heating surface 1 : 11.73 1 : 13.29
Grate area/Heating surface 1 : 75.04 1 : 72.85
Firebox/Tube surface 1 : 11.78 1 : 11.20
Total/Superheater 1 : 4.10 1 : 3.78
Auf Deutsch umschalten

Settings

Your settings are retained for this browser session only.

Consent to cookies

We use cookies to save your display settings. If you decline, the settings are retained only for the current browser session.