Rutland class G-34
United States 1907 18 produced
Between 1907 and 1913, ALCO-Schenectady built 18 high-boilered Consolidations for the Rutland Railroad. They were delivered in four batches of 6, 4, 2 and 6 which formed the classes G-34a to G-34d. As delivered they worked on saturated steam, but were superheated later. Since the New York Central was in control over the Rutland when they were delivered, they got the NYC numbers 2414 to 2431 but were only used on Rutland trackage. When the Rutland became independent again in 1914, they just lost the “24” in front of their numbers. When some were used for express freights in the thirties, they were apparently semi-streamlined around the running boards. Retirements started in 1939 and were completed by 1952.
Technical data
General
| Property | as built | superheated |
|---|---|---|
| Built | 1907-1913 | |
| Manufacturers | ALCO | |
| Wheel arrangement | 2-8-0 (Consolidation) | |
| Gauge | 1,435 mm (Standard gauge) | |
Dimensions and weights
| Property | as built | superheated |
|---|---|---|
| Wheelbase | 7.85 m | |
| Total wheelbase | 18.33 m | |
| Service mass | 95.7 t | 97.1 t |
| Adhesion mass | 84.8 t | 85.5 t |
| Total mass | 162.6 t | 163.9 t |
| Rigid wheelbase | 5.18 m | |
| Axle load | 21.2 t | 21.4 t |
| Water capacity | 28,391 l | |
| Fuel capacity | 10.9 t (coal) | |
Boiler
| Property | as built | superheated |
|---|---|---|
| Grate area | 4.667 m² | 4.664 m² |
| Firebox surface | 17.466 m² | 16.908 m² |
| Tube heating surface | 303.329 m² | 224.64 m² |
| Evaporative heating surface | 320.795 m² | 241.548 m² |
| Total heating surface | 320.8 m² | 291.5 m² |
| Superheater surface | 49.982 m² |
Power plant
| Property | as built | superheated |
|---|---|---|
| Driver diameter | 1,600 mm | |
| Boiler pressure | 13.4 bar | |
| Expansion type | simple expansion | |
| Cylinders | two, 559 x 762 mm | two, 572 x 762 mm |
Power
| Property | as built | superheated |
|---|---|---|
| Power source | steam | |
| Estimated power | 1,268 kW | 1,342 kW |
| Starting effort | 169.9 kN | 177.7 kN |
Calculated values
| Property | as built | superheated |
|---|---|---|
| Factor of adhesion | 1 : 4.90 | 1 : 4.72 |
| Optimal speed | 45 km/h | 47 km/h |
| Power-to-weight ratio | 13.2 kW/t | 13.8 kW/t |
| Heating Surface Equivalent | 408.1 m² | 426.1 m² |
| Cylinder volume/HSE | 1 : 915.79 | 1 : 917.58 |
| Adhesive weight/Total | 1 : 1.13 | 1 : 1.14 |
| Tractive force/Heating surface | 1 : 11.06 | 1 : 12.73 |
| Grate area/Heating surface | 1 : 68.74 | 1 : 62.51 |
| Firebox/Tube surface | 1 : 17.37 | 1 : 13.29 |
| Total/Superheater | 1 : 4.83 |