Southern Pacific classes GS-1 and GS-2
In 1930, the Southern Pacific used its Mountains as a base and installed a larger firebox, now supported by a two-axle bogie. This resulted in the GS-1, which was intended for passenger and express trains with a driver diameter of 73.5 inches or 1,867 mm and was built by Baldwin. GS stood for “Golden State” or later “General Service”. Ten GS-1 were delivered directly to the Southern Pacific and four to the Texas & Louisiana Lines.
In 1937 six GS-2s were delivered from Lima. They were almost identical to the GS-1, but had colorful streamlined fairing, making them about 6,000 pounds heavier. The famous GS-3 to GS-5, which had larger drivers, were later built with the same fairing. Since the GS-1 and -2 soon no longer had to pull the fastest trains, they were considered for heavy commuter trains. Especially in the San Francisco area, they had to prove their power in demanding schedules until the second half of the 1950s.
Technical data
General
| Property | GS-1 | GS-2 |
|---|---|---|
| Built | 1930 | 1937 |
| Manufacturers | Baldwin | Lima |
| Wheel arrangement | 4-8-4 (Northern) | |
| Gauge | 1,435 mm (Standard gauge) | |
Dimensions and weights
| Property | GS-1 | GS-2 |
|---|---|---|
| Wheelbase | 13.97 m | |
| Total wheelbase | 26.90 m | 28.66 m |
| Service mass | 200.6 t | 203.4 t |
| Adhesion mass | 118.8 t | 120.9 t |
| Total mass | 332.6 t | 372.6 t |
| Rigid wheelbase | 6.10 m | |
| Axle load | 30.4 t | |
| Water capacity | 61,134 l | 81,765 l |
| Fuel capacity | 17,754 l (oil) | 23,753 l (oil) |
Boiler
| Property | GS-1 | GS-2 |
|---|---|---|
| Grate area | 8.38 m² | |
| Firebox surface | 33.074 m² | |
| Tube heating surface | 418.25 m² | |
| Evaporative heating surface | 451.323 m² | |
| Superheater surface | 238.297 m² | |
| Total heating surface | 689.6 m² | |
Power plant
| Property | GS-1 | GS-2 |
|---|---|---|
| Driver diameter | 1,867 mm | |
| Boiler pressure | 17.2 bar | |
| Expansion type | simple expansion | |
| Cylinders | two, 686 x 762 mm | |
Power
| Property | GS-1 | GS-2 |
|---|---|---|
| Power source | steam | |
| Estimated power | 3,468 kW (4,715 PS) | |
| Starting effort | 281.3 kN | |
Calculated values
| Property | GS-1 | GS-2 |
|---|---|---|
| Factor of adhesion | 1 : 4.15 | 1 : 4.22 |
| Optimal speed | 76 km/h | |
| Power-to-weight ratio | 17.3 kW/t | 17.1 kW/t |
| Heating Surface Equivalent | 1,093.3 m² | |
| Cylinder volume/HSE | 1 : 514.91 | |
| Adhesive weight/Total | 1 : 1.69 | 1 : 1.68 |
| Tractive force/Heating surface | 1 : 8.52 | |
| Grate area/Heating surface | 1 : 82.29 | |
| Firebox/Tube surface | 1 : 12.65 | |