London, Midland & Scottish Stanier 3P 2-6-2T

Great Britain 1935 139 produced
flickr/stratfordman72

Stanier developed these locos from Fowler's 2-6-2T. The biggest change was in the new boiler, which was tapered towards the front. The locomotives with the numbers 71 to 120 and 121 to 144 each used a slightly different variant of boiler type No. 6 without a dome. Numbers 145 to 209 had boiler no. 6A with a feed and a steam dome. In general, the locomotives are referred to as Stanier's least successful design. Among other things, the extremely small superheater surface is mentioned. Six of them were later given the 6B boiler, but this was not cost-effective. Nevertheless, they were only withdrawn between 1959 and 1962.

Technical data

General

Property 71-120 121-144 145-209 rebuilt 6B boiler
Built 1935 1937-1938 1940-1956
Manufacturers Derby Derby, Crewe Crewe
Wheel arrangement 2-6-2T (Prairie)
Gauge 1,435 mm (Standard gauge)

Dimensions and weights

Property 71-120 121-144 145-209 rebuilt 6B boiler
Length 12.80 m
Wheelbase 10.14 m
Service mass 71.9 t 72.4 t 73.7 t
Adhesion mass 47.2 t
Rigid wheelbase 5.03 m
Axle load 15.7 t
Water capacity 6,818 l
Fuel capacity 3 t (coal)

Boiler

Property 71-120 121-144 145-209 rebuilt 6B boiler
Grate area 1.626 m² 1.788 m²
Firebox surface 9.662 m² 9.941 m² 10.312 m²
Tube heating surface 72 m² 79.804 m² 87.236 m² 92.624 m²
Evaporative heating surface 81.662 m² 89.744 m² 97.177 m² 102.937 m²
Superheater surface 6.782 m² 7.061 m² 7.432 m² 12.821 m²
Total heating surface 88.4 m² 96.8 m² 104.6 m² 115.8 m²

Power plant

Property 71-120 121-144 145-209 rebuilt 6B boiler
Driver diameter 1,600 mm
Boiler pressure 13.8 bar
Expansion type simple expansion
Cylinders two, 444 x 660 mm

Power

Property 71-120 121-144 145-209 rebuilt 6B boiler
Power source steam
Estimated power 619 kW (842 PS) 671 kW (912 PS) 690 kW (938 PS) 708 kW (963 PS)
Starting effort 95.6 kN

Calculated values

Property 71-120 121-144 145-209 rebuilt 6B boiler
Factor of adhesion 1 : 4.84
Optimal speed 40 km/h 43 km/h 45 km/h
Power-to-weight ratio 8.6 kW/t 9.3 kW/t 9.5 kW/t 9.6 kW/t
Heating Surface Equivalent 143.5 m² 153.6 m² 161.7 m² 180.1 m²
Cylinder volume/HSE 1 : 1,427.94 1 : 1,334.62 1 : 1,267.18 1 : 1,137.80
Adhesive weight/Total 1 : 1.52 1 : 1.53 1 : 1.56
Tractive force/Heating surface 1 : 22.57 1 : 20.62 1 : 19.08 1 : 17.24
Grate area/Heating surface 1 : 54.39 1 : 54.14 1 : 58.51 1 : 64.74
Firebox/Tube surface 1 : 7.45 1 : 8.03 1 : 8.78 1 : 8.98
Total/Superheater 1 : 12.04 1 : 12.71 1 : 13.08 1 : 8.03
Auf Deutsch umschalten

Settings

Your settings are retained for this browser session only.

Consent to cookies