Caledonian classes 49 and 903 “Cardean”
The Caledonian Railway had to operate many express trains with two 4-4-0 locomotives and also needed a helper locomotive at Beattock Summit. To improve this, McIntosh developed a 4-6-0 in 1903. Initially these were just two locomotives, numbers 49 and 50, which were based on the Dunalastair and had inside cylinders. Although these became the flagship of the CR, their performance was not outstanding and there were no sufficiently long turntables.
After longer turntables were built, McIntosh had five improved locomotives built, numbers 903 to 907. The 903 was the only one in the new series to be given the name “Cardean” and thus gave rise to the nickname of the class. All of them received a superheater in 1911, but due to the reduced boiler pressure they hardly had any noticeable increase in output.
However, since this reduced coal consumption, all of them were taken over by the LMS in 1923. There they were soon eclipsed by the LMS Compound and Royal Scot. They were retired between 1927 and 1933, with the exception of the 907, which was written off in 1915 after Britain's worst rail disaster.
Technical data
General
| Property | 49 | 903 | superheated |
|---|---|---|---|
| Built | 1903 | 1906 | 1911 |
| Manufacturers | St. Rollox | ||
| Wheel arrangement | 4-6-0 (Ten-wheeler) | ||
| Gauge | 1,435 mm (Standard gauge) | 0 mm | |
Dimensions and weights
| Property | 49 | 903 | superheated |
|---|---|---|---|
| Wheelbase | 8.74 m | ||
| Service mass | 74 t | 73.1 t | 67.4 t |
| Adhesion mass | 55.9 t | 55.4 t | 55.8 t |
| Total mass | 130.1 t | 131 t | 125.3 t |
| Rigid wheelbase | 4.57 m | ||
| Axle load | 18.8 t | ||
| Water capacity | 22,731 l | ||
| Fuel capacity | 6.1 t (coal) | 5.1 t (coal) | |
| Total wheelbase | 17.32 m | ||
Boiler
| Property | 49 | 903 | superheated |
|---|---|---|---|
| Grate area | 2.415 m² | ||
| Firebox surface | 13.471 m² | 13.773 m² | |
| Tube heating surface | 209.497 m² | 215.071 m² | 154.753 m² |
| Evaporative heating surface | 222.968 m² | 228.542 m² | 168.526 m² |
| Total heating surface | 223.0 m² | 228.5 m² | 216.5 m² |
| Superheater surface | 47.938 m² | ||
Power plant
| Property | 49 | 903 | superheated |
|---|---|---|---|
| Driver diameter | 1,981 mm | ||
| Boiler pressure | 13.8 bar | 12.1 bar | |
| Expansion type | simple expansion | ||
| Cylinders | two, 533 x 660 mm | two, 508 x 660 mm | two, 527 x 660 mm |
Power
| Property | 49 | 903 | superheated |
|---|---|---|---|
| Power source | steam | ||
| Estimated power | 783 kW (1,065 PS) | 790 kW (1,074 PS) | 802 kW (1,090 PS) |
| Starting effort | 111.2 kN | 100.8 kN | 95.0 kN |
Calculated values
| Property | 49 | 903 | superheated |
|---|---|---|---|
| Factor of adhesion | 1 : 4.93 | 1 : 5.39 | 1 : 5.76 |
| Optimal speed | 43 km/h | 48 km/h | 51 km/h |
| Power-to-weight ratio | 10.6 kW/t | 10.8 kW/t | 11.9 kW/t |
| Heating Surface Equivalent | 290.3 m² | 295.9 m² | 333.3 m² |
| Cylinder volume/HSE | 1 : 1,016.60 | 1 : 904.72 | 1 : 864.65 |
| Adhesive weight/Total | 1 : 1.33 | 1 : 1.32 | 1 : 1.21 |
| Tractive force/Heating surface | 1 : 10.41 | 1 : 9.21 | 1 : 9.16 |
| Grate area/Heating surface | 1 : 92.33 | 1 : 94.63 | 1 : 89.63 |
| Firebox/Tube surface | 1 : 15.55 | 1 : 15.97 | 1 : 11.24 |
| Total/Superheater | 1 : 3.52 |